A list of the most recent deficiencies for King's Grant Retirement Commun. The list is based on the information provided by CMS from both standard inspections and from complaints filed by residents.

Deficiency Type of Deficiency Deficiency Date Date Corrected Resulted from a Complaint?
Have properly located and lighted "Exit" signs. Fire Safety 2019-09-24 2019-10-29 N
Have approved installation, maintenance and testing program for fire alarm systems. Fire Safety 2019-09-24 2019-10-29 N
Inspect, test, and maintain automatic sprinkler systems. Fire Safety 2019-09-24 2019-10-29 N
Install smoke barrier doors that can resist smoke for at least 20 minutes. Fire Safety 2019-09-24 2019-10-29 N
Provide a written emergency evacuation plan. Fire Safety 2019-09-24 2019-10-29 N
Have restrictions on the use of flammable curtains. Fire Safety 2019-09-24 2019-10-29 N
Provide exit doors that are held open by devices that will automatically close on the activation of a fire alarm or smoke detector. Fire Safety 2018-10-11 2018-11-15 N
Have properly located and lighted "Exit" signs. Fire Safety 2018-10-11 2018-11-15 N
Have properly installed hallway dispensers for alcohol-based hand rub. Fire Safety 2018-10-11 2018-11-15 N
Inspect, test, and maintain automatic sprinkler systems. Fire Safety 2018-10-11 2018-11-15 N
Properly select, install, inspect, or maintain portable fire extinguishes. Fire Safety 2018-10-11 2018-11-15 N
Have simulated fire drills held at unexpected times. Fire Safety 2018-10-11 2018-11-15 N
Have generator or other power source capable of supplying service within 10 seconds. Fire Safety 2018-10-11 2018-11-15 N
Ensure proper usage of power strips and extension cords. Fire Safety 2018-10-11 2018-11-15 N
Ensure that testing and maintenance of electrical equipment is performed. Fire Safety 2018-10-11 2018-11-15 N
Provide appropriate treatment and care according to orders, resident?s preferences and goals. Health 2018-09-20 2018-11-03 N
Procure food from sources approved or considered satisfactory and store, prepare, distribute and serve food in accordance with professional standards. Health 2018-09-20 2018-11-03 N
Have properly located and lighted "Exit" signs. Fire Safety 2017-06-28 2017-08-14 N
Have approved installation, maintenance and testing program for fire alarm systems. Fire Safety 2017-06-28 2017-08-14 N
Ensure that building systems meet requirements determined by risk assessment procedures performed by qualified personnel. Fire Safety 2017-06-28 2017-08-14 N
Have proper power supply for life support equipment. Fire Safety 2017-06-28 2017-08-14 N
Have generator or other power source capable of supplying service within 10 seconds. Fire Safety 2017-06-28 2017-08-14 N
Ensure that testing and maintenance of electrical equipment is performed. Fire Safety 2017-06-28 2017-08-14 N
Have proper medical gas storage and administration areas. Fire Safety 2017-06-28 2017-08-14 N