Deficiency Type of Deficiency Deficiency Date Date Corrected Resulted from a Complaint?
Provide necessary care and services to maintain or improve the highest well being of each resident . Health 2016-12-15 2017-01-31 N
1) Hire only people with no legal history of abusing, neglecting or mistreating residents; or 2) report and investigate any acts or reports of abuse, neglect or mistreatment of residents. Health 2016-05-21 2016-06-20 Y
Develop and implement policies for 1) screening and training employees; and the 2) prevention, identification, investigation, and reporting of any abuse, neglect, mistreatment and misappropriation of property. Health 2016-05-21 2016-06-20 Y
Special areas constructed so that walls can resist fire for one hour or an approved fire extinguishing system. Fire Safety 2015-09-09 2015-10-15 N
Record of quarterly fire drills for each shift under varying conditions. Fire Safety 2015-09-09 2015-10-15 N
An approved installation, maintenance and testing program for fire alarm systems. Fire Safety 2015-09-09 2015-10-15 N
Automatic sprinkler systems that have been maintained in working order. Fire Safety 2015-09-09 2015-10-15 N
Proper medical gas storage and administration areas. Fire Safety 2015-09-09 2015-10-15 N
Corridors that are separated from use areas by walls constructed to limit the passage of smoke. Fire Safety 2014-06-10 2014-08-01 N
Corridor and hallway doors that block smoke. Fire Safety 2014-06-10 2014-08-01 N
Walls that prevent smoke from passing through and would resist fire for at least one hour. Fire Safety 2014-06-10 2014-08-01 N
Special areas constructed so that walls can resist fire for one hour or an approved fire extinguishing system. Fire Safety 2014-06-10 2014-08-01 N
Exits that are accessible at all times. Fire Safety 2014-06-10 2014-08-01 N
Proper backup exit lighting. Fire Safety 2014-06-10 2014-08-01 N
Emergency lighting that can last at least 1 1/2 hours. Fire Safety 2014-06-10 2014-08-01 N
A written emergency evacuation plan. Fire Safety 2014-06-10 2014-08-01 N
Record of quarterly fire drills for each shift under varying conditions. Fire Safety 2014-06-10 2014-08-01 N
A fire alarm system that can be heard throughout the facility. Fire Safety 2014-06-10 2014-08-01 N
An approved installation, maintenance and testing program for fire alarm systems. Fire Safety 2014-06-10 2014-08-01 N
Automatic sprinkler systems that have been maintained in working order. Fire Safety 2014-06-10 2014-08-01 N
Heating and ventilation systems that have been properly installed according to the manufacturer's instructions. Fire Safety 2014-06-10 2014-08-01 N
Properly protected cooking facilities. Fire Safety 2014-06-10 2014-08-01 N
Exits that are free from obstructions and can be used at all times. Fire Safety 2014-06-10 2014-08-01 N
Restrictions on the use of flammable curtains. Fire Safety 2014-06-10 2014-08-01 N
Proper medical gas storage and administration areas. Fire Safety 2014-06-10 2014-08-01 N
Weekly inspections and monthly testing of generators. Fire Safety 2014-06-10 2014-08-01 N
Properly installed electrical wiring and equipment. Fire Safety 2014-06-10 2014-08-01 N
Provide a safe, clean, comfortable and home-like environment; and allow residents to use personal belongings to the extent possible. Health 2014-06-12 2014-08-01 N