Deficiency Records for Correctionville Specialty Care
Updated as of May 01, 2021
This is not the most recent data for Correctionville Specialty Care. For the most recent information, click here.
A list of the most recent deficiencies for Correctionville Specialty Care. The list is based on the information provided by CMS from both standard inspections and from complaints filed by residents.
Deficiency | Type of Deficiency | Deficiency Date | Date Corrected | Resulted from a Complaint? |
---|---|---|---|---|
Create and put into place a plan for meeting the resident's most immediate needs within 48 hours of being admitted | Health | 2021-03-01 | 2021-04-01 | N |
Provide appropriate care for residents who are continent or incontinent of bowel/bladder, appropriate catheter care, and appropriate care to prevent urinary tract infections. | Health | 2021-03-01 | 2021-04-01 | N |
Provide and implement an infection prevention and control program. | Health | 2021-03-01 | 2021-04-01 | N |
Immediately tell the resident, the resident's doctor, and a family member of situations (injury/decline/room, etc.) that affect the resident. | Health | 2021-03-01 | 2021-04-01 | Y |
Install emergency lighting that can last at least 1 1/2 hours. | Fire Safety | 2021-02-24 | 2021-03-08 | N |
Ensure proper usage of power strips and extension cords. | Fire Safety | 2021-02-24 | 2021-03-05 | N |
Install corridor and hallway doors that block smoke. | Fire Safety | 2021-02-24 | 2021-03-04 | N |
Have simulated fire drills held at unexpected times. | Fire Safety | 2021-02-24 | 2021-03-04 | N |
Inspect, test, and maintain automatic sprinkler systems. | Fire Safety | 2021-02-24 | 2021-03-03 | N |
Notify the resident or the resident?s representative in writing how long the nursing home will hold the resident?s bed in cases of transfer to a hospital or therapeutic leave. | Health | 2019-04-04 | 2019-05-04 | N |
Procure food from sources approved or considered satisfactory and store, prepare, distribute and serve food in accordance with professional standards. | Health | 2019-04-04 | 2019-05-04 | N |
Have exits that are accessible at all times. | Fire Safety | 2019-04-08 | 2019-04-15 | N |
Inspect, test, and maintain automatic sprinkler systems. | Fire Safety | 2019-04-08 | 2019-04-15 | N |
Ensure proper usage of power strips and extension cords. | Fire Safety | 2019-04-08 | 2019-04-15 | N |
Ensure that special areas are constructed so that walls can resist fire for one hour or have an approved fire extinguishing system. | Fire Safety | 2017-11-20 | 2017-11-27 | N |
Inspect, test, and maintain automatic sprinkler systems. | Fire Safety | 2017-11-20 | 2017-11-27 | N |
Install corridor and hallway doors that block smoke. | Fire Safety | 2017-11-20 | 2017-11-27 | N |
Have properly installed electrical wiring and gas equipment. | Fire Safety | 2017-11-20 | 2017-11-27 | N |